1InstallationandOperationInstructionsJøtul GF 600 DVFirelightDirect Vent GasHeaterIF THE INFORMATION IN THESE INSTRUC-TIONS ARE NOT FOLLOWED EXACTLY,
10Simpson Dura-Vent ChimneyConversion KitThe GF 600 DV Firelight is approved for usewith Simpson Dura-vent Chimney Kits asshown in Figure 8. These ins
11ANY VENTING WITH A VERTICAL RISE MUST TERMI-NATE (END) WITHIN THE SHADED AREA.Restrictors required on:• All Co-linear (flex pipe)• All coaxial (rigi
12CLHorizontal Termination The horizontal termination cap must maintain a3” clearance to any overhead combustibleprojections that are 2 1/2” or less.
13376 mm12 305mm2 1/264 mmFigure 12. Horizontal Termination Clearance* As specified in CGA B149 Installation Codes. Note: Local Codes and Regulati
14Conversion Kit (LPG #154391, NG # 154392)Tools required:• 1/4” nut driver• 1/2” & 13 mm open end wrench or deep-wellsocket• Torx T20 or slo
15Figure 12. Remove the Air Divider and Log Support.Gas Conversion ProcedureAll numbers in ( ) refer to the exploded view onpage 25 of this manual.1.
1617. Replace the variable regulator. Using a Torx T-20screwdriver, remove the three specialty screwsfrom the HI/LO regulator on the front of thevalve
17Leak test:1. Mix a 50-50 solution of water and dish soap.2. Light appliance- see lighting instructions on page22 of this manual or on the stove’s ra
18High Altitude AdjustmentWhen installing the GF 600 DV Firelight gas stove inhigh altitude situations (above 2500') it becomesnecessary to compe
19Air Shutter Adjustment / FlameAppearanceThe GF 600 DV FIRELIGHT gas stove is shipped fromthe factory equipped as a NATURAL GAS STOVE. Ifthe stove i
2Welcome to Jøtul...Congratulations on the purchase of your newGF 600 DV Firelight Gas Heater.We at Jøtul are glad you’ve made the decision towarm you
20Install the Log SetThe four-piece log set is packaged in bubble wrapinside the firebox.Do not handle the log set with your barehands. Always wear
21Optional ControlsWall ThermostatUse only a 750 millivolt DC two-wire circuit ther-mostat, placed in the same room as the heater,typically 5’ off the
223. BURNER ADJUSTMENT: The Jøtul GF 600 DVFirelight gas stove is equipped with a variablegas control valve that provides easy adjustmentof the flam
23Connect the Wiring Harness1. Locate the switch bracket on the back of thestove, below the burner control switch.2. Remove the four 1/4” hex head scr
24MaintenanceThe GF 600 DV Firelight gas stove and its ventingsystem should be inspected before use and at leastannually by a qualified service techni
25123456784910111314151617181920212223242526272829303132333435363738Firelight GF 600 DVParts Identification
26 * NOT SHOWN in exploded view diagramCast Iron Part Matte Black Blue Black Ivory Green Indigo1 Left Door 10332192 103416 103444 10332132 103321362 R
277. Push in gas control knob slightly and turn counter-clockwise to “PILOT”.8. Push in control knob all the way and hold in.Immediately light the pi
28notes:This appliance must be installed in conformance with local and nationalbuilding regulations. It is important that the these instructions be re
3Table of ContentsService Tools ... 3Specifications ... 4General In
4GF 600 DV FirelightSpecificationsInput RatesNatural Gas40,000 BTU/hr. maximum input28,600 BTU/hr. minimum inputPropane40,000 BTU/hr. maximum input30,
5General Information THIS HEATER MUST BE INSTALLED AND MAIN-TAINED BY A QUALIFIED SERVICE AGENCY. The installation and repair of this appliance must
6LocationIn selecting the location, the aesthetic and func-tional use of the appliance are primary concerns.However, proper venting systems and access
7ALCOVE:MAXIMUM ALCOVE DEPTH: 24” (61 cm)MINIMUM ALCOVE WIDTH: 44” (112 cm)MINIMUM CEILING HEIGHT: 64” (163 mm)Stove and Vent ClearanceRe
8Vent RestrictionThe GF 600 DV Firelight includes two rectangularExhaust Restrictor plates and one square Air InletRestrictor Plate as shown in Figure
9EXHAUST RESTRICTORS REQUIRED ON ALLCO-LINEAR INSTALLATIONS.ALWAYS MAINTAIN THE PROPERCLEARANCES TO COMBUSTIBLES.Co-linear Hearthmount Installation Th